12.1 inch multi-parameter patient monitor
|
Supply Ability: |
10000 |
Related proudcts |
patient monitor, vital signs monitor, medical monitor, |
Specifications |
size:12.1 inch weight:3.5kg |
Price Term: |
EXW |
Port of loading: |
|
Minimum Order |
1 set |
Unit Price: |
265.85$ |
|
6 parameters:ECG,HR,SPO2,NIBP,RESP, TEMP Leads:3-5 leads Technology: Digital Oxygen Technology Body material:All aluminum internal Structure Suitable places:Bedside care ward, ICU, CCU, operating theaters, emergency centers, family care and the like. Optional :Build-in lithium battery, thermal printer, mobile stand/cart/trolley, wall bracket. SFDA classification:Class II Working system :Continuous running equipment
Standard configuration: PM-9000A+ patient multi parameter monitor¡Á1 set, standard 5-leads ECG conductance joint connecting cables¡Á1 set, standard adult blood pressure cuffs¡Á1 set, adult SPO2 probe¡Á1 set, TEMP probe¡Á1 set, power plug line¡Á1 set, grounding wire¡Á1 set, English operation manual¡Á1 set. Three certificates¡Á1 set.
Optional: Build-in rechargeable lithium battery; build-in thermal printer; monitor mobile stand/ cart.
Technical parameters
ECG measurement£º Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed Gains options: ¡Á 1, ¡Á 2, ¡Á 0.25, and ¡Á0.5 four trenches Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ¡À 5 bpm Precision calibration signal: 1mv(peak, ¡À 3% accuracy) ST ***ection: measurement range (-1.0mV----+1.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable
NIBP measurement Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Protection: Double security protection A measurement time: less than 45 S Scope: Pressure Cuffs 0-250 mmHg Blood pressure measurement accuracy: ANSI /AAMI, SP10-2002 standard error and standard deviation of the average value of the initial Inflatable cuffs: 180 mmHg (children 120mmHg) Inflatable cuffs follow: original SBP: + 30 mmHg Blood pressure measuring range: Systolic |